Mfg Part Number : 120-1065-02 | Alternate P/N : 120106502 |
Manufacturer : Multicomp Corporation | NSN : 5950-01-346-1695 |
CAGE Code : 75498 | Item Name : transformer power |
The National Stock Number, or NSN, is the 13-digit serial number assigned by the Defense Logistics Agency (DLA) to all items in the federal supply chain. Are you interested in learning more about 120-1065-02? If so, feel free to call us at +1-714-705-4780 or email us at sales@asap-partsonline.com. We’re available 24/7x365. If you’re looking for a faster and even more convenient purchasing platform, download the ASAP Semiconductor App from Google Play or the App Store.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-346-1695 Item Description: Transformerpower | 5950 | 013461695 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
120-1065-02 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ACZB | FREQUENCY RATING | 20 0 KILOHERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AXGY | MOUNTING METHOD | BRACKET SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 14 WIRE LEAD |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 3 075 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 1 800 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1 285 INCHES NOMINAL |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT AND INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
AGAV | END ITEM IDENTIFICATION | 6625-01-279-3446OSCILLOSCOPE |
AKNA | INCLOSURE TYPE | OPEN |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |
CBBL | FEATURES PROVIDED | TINNED WIRE LEADS |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 103 0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY5 0 MILLIAMPERES DC MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 15 0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY1 0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6 30 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY297 00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY134 00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY AND 268 00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECOND |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2 258 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2 318 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0 700 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
If You Have Multiple Parts Requirement, Then Upload Your Part List Here !
Upload
All Orders are fulfilled in the USA.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
Don't Forget That We Can Give You a Quote for Parts Within 15 Minutes If You Fill Out The Instant RFQ Form On Our Page.
Request for Quote