Are you in need of part numbers 45301, G146-433-001, G5162-734 from Electronic Transformer Corp, Bae Systems Information And Electronic Systems Integration Inc, Kearfott Corporation manufacturers of NSN 5950009420268? ASAP Parts Online has the part number in stock and ready to be shipped. Along with NSN 5950009420268 corresponding part numbers, we have access to billions of premium parts such as Transformer Power for the aviation, defense, and military industries. We are here to help streamline the process.
Alternative NSN: 5950-00-942-0268 |
Item Name:Transformer Power |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5950 Coils and Transformers |
NIIN: 009420268 |
NCB Code: USA (00) |
Manufacturers: Bae Systems Information And Electronic Systems Integration Inc , Electronic Transformer Corp , Kearfott Corporation |
Part No Part No
|
Item Name Item Name
|
Manufacturer Manufacturer
|
QTY QTY
|
RFQ RFQ
|
---|---|---|---|---|
45301 | transformer power | Electronic Transformer Corp | Avl |
|
G146-433-001 | transformer power | Bae Systems Information And Electronic Systems Integration Inc | Avl |
|
G146-433-001 | transformer power | Kearfott Corporation | Avl |
|
G5162-734 | transformer power | Kearfott Corporation | Avl |
|
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT" |
ADAQ | BODY LENGTH | 2.656 INCHES NOMINAL" |
ADAT | BODY WIDTH | 2.156 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 2.062 INCHES NOMINAL" |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED" |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP" |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP" |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY, VARIABLE AUTOTRANSFORMER TYPE SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT" |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP" |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP" |
CRBZ | WINDING OPERATING CURRENT | 1.1 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 550.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 550.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY OR 50.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 46.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 80.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 80.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY" |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP" |
TTQY | TERMINAL TYPE AND QUANTITY | 13 TAB, SOLDER LUG" |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT" |
ADAQ | BODY LENGTH | 2.656 INCHES NOMINAL" |
ADAT | BODY WIDTH | 2.156 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 2.062 INCHES NOMINAL" |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED" |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP" |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP" |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY, VARIABLE AUTOTRANSFORMER TYPE SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT" |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP" |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP" |
CRBZ | WINDING OPERATING CURRENT | 1.1 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 550.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 550.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY OR 50.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 46.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 80.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 80.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY" |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP" |
TTQY | TERMINAL TYPE AND QUANTITY | 13 TAB, SOLDER LUG" |
Guaranteed quotes back within
5 minutes, 24/7 x 365
All Orders are fulfilled in the USA.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
Don't Forget That We Can Give You a Quote for Parts Within 15 Minutes If You Fill Out The Instant RFQ Form On Our Page.
Request for Quote