Are you in need of part numbers 507004AM, 8501PH22E, CA2DN1229FA60, CA2DN22G6 from Telenor Comma A S, Schneider Electric Usa Inc, Telemecanique Inc, Allied Controls Inc manufacturers of NSN 5945012125466? ASAP Parts Online has the part number in stock and ready to be shipped. Along with NSN 5945012125466 corresponding part numbers, we have access to billions of premium parts such as Relay Electromagnet for the aviation, defense, and military industries. We are here to help streamline the process.
Alternative NSN: 5945-01-212-5466 |
Item Name:Relay Electromagnet |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5945 Relays and Solenoids |
NIIN: 012125466 |
NCB Code: USA (01) |
Manufacturers: Allied Controls Inc , Schneider Electric Usa Inc , Telemecanique Inc , Telenor Comma A S |
Part No Part No
|
Item Name Item Name
|
Manufacturer Manufacturer
|
QTY QTY
|
RFQ RFQ
|
---|---|---|---|---|
507004AM | relay electromagnet | Telenor Comma A S | Avl |
|
8501PH22E | relay electromagnet | Schneider Electric Usa Inc | Avl |
|
CA2DN1229FA60 | relay electromagnet | Schneider Electric Usa Inc | Avl |
|
CA2DN22G6 | relay electromagnet | Telemecanique Inc | Avl |
|
CA2DN22G6 | relay electromagnet | Schneider Electric Usa Inc | Avl |
|
CA2DN22G6 | relay electromagnet | Allied Controls Inc | Avl |
|
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2 625 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 3 156 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1 750 INCHES NOMINAL |
ADTV | CASE MATERIAL | METAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJSS | FREQUENCY IN HERTZ | 60 0 NOMINAL |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 TERMINAL SINGLE MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBME | CUBIC MEASURE | 14 497 CUBIC INCHES |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE SINGLE THROW NORMALLY OPEN MOMENTARY ACTION AND 2 POLE SINGLE THROW NORMALLY CLOSED MOMENTARY ACTION |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 120 0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 12 0 AMPERES AC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 600 0 AC |
TTQY | TERMINAL TYPE AND QUANTITY | 10 SCREW ALL FUNCTIONS |
Guaranteed quotes back within
5 minutes, 24/7 x 365
All Orders are fulfilled in the USA.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
Don't Forget That We Can Give You a Quote for Parts Within 15 Minutes If You Fill Out The Instant RFQ Form On Our Page.
Request for Quote