Are you in need of part numbers KB3090 from Eaton Corporation manufacturers of NSN 5925012787968? ASAP Parts Online has the part number in stock and ready to be shipped. Along with NSN 5925012787968 corresponding part numbers, we have access to billions of premium parts such as Circuit Breaker for the aviation, defense, and military industries. We are here to help streamline the process.
Alternative NSN: 5925-01-278-7968 |
Item Name:Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 012787968 |
NCB Code: USA (01) |
Manufacturers: Eaton Corporation |
Part No Part No
|
Item Name Item Name
|
Manufacturer Manufacturer
|
QTY QTY
|
RFQ RFQ
|
---|---|---|---|---|
KB3090 | circuit breaker | Eaton Corporation | Avl |
|
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 7.940 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 90.0 AMPERES AC ALL LOCATIONS |
AKPX | Pole Quantity | 3 |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 600.0 AC ALL LOCATIONS |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 900.0 AC ALL LOCATIONS |
CRCF | Trip Release Ambient Temp Rating | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPRL | Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 1.375 INCHES NOMINAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
AJEC | Boss Height | 0.187 INCHES NOMINAL |
CPRQ | Reset Method | MANUAL |
CPRW | Actuator Function | TRIP-RESET |
AXHR | Mounting Facility Type And Quantity | 4 UNTHREADED HOLE |
CPRX | Actuator Position Designation | AT POLE TWO |
ADTV | Case Material | PLASTIC |
ADAT | Body Width | 4.125 INCHES NOMINAL |
CPSF | Adjustable Trip Setting Current Range Per Pole In Amps | +450.0/+900.0 AC ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 6 COMPRESSION |
CBBL | Features Provided | ADJUSTABLE TRIP RELEASE |
MRC | Decoded Requirement | Clear Text Reply |
ADAQ | Body Length | 10.000 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 8.375 INCHES NOMINAL |
ADAU | Body Height | 4.062 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 1.375 INCHES NOMINAL |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
AEBV | Unthreaded Mounting Hole Diameter | 0.281 INCHES NOMINAL |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
Guaranteed quotes back within
5 minutes, 24/7 x 365
All Orders are fulfilled in the USA.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
Don't Forget That We Can Give You a Quote for Parts Within 15 Minutes If You Fill Out The Instant RFQ Form On Our Page.
Request for Quote