Are you in need of part numbers UPG-6-1-REC3-52-253-9 from Sensata Technologies Inc manufacturers of NSN 5925012046888? ASAP Parts Online has the part number in stock and ready to be shipped. Along with NSN 5925012046888 corresponding part numbers, we have access to billions of premium parts such as Circuit Breaker for the aviation, defense, and military industries. We are here to help streamline the process.
Alternative NSN: 5925-01-204-6888 |
Item Name:Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 012046888 |
NCB Code: USA (01) |
Manufacturers: Sensata Technologies Inc |
Part No Part No
|
Item Name Item Name
|
Manufacturer Manufacturer
|
QTY QTY
|
RFQ RFQ
|
---|---|---|---|---|
UPG-6-1-REC3-52-253-9 | circuit breaker | Sensata Technologies Inc | Avl |
|
MRC | Criteria | Characteristic |
---|---|---|
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 1.645 INCHES MINIMUM AND 1.675 INCHES MAXIMUM |
FEAT | Special Features | WHITE HANDLE WITH WHITE MARKINGS |
AAQL | Body Style | SINGLE POLE TYPE |
BBRJ | Special Handling Feature | MAGNETIC |
CQXF | Inclosure Protection Type For Which Designed | MOISTURE RESISTANT AND SALT SPRAY PROOF AND SHOCK RESISTANT AND VIBRATION RESISTANT |
AKPX | Pole Quantity | 1 |
CPLM | Maximum Continuous Load Current Rating Per Pole | 25.0 AMPERES DC SINGLE LOCATION |
AJEC | Boss Height | 0.115 INCHES MINIMUM AND 0.145 INCHES MAXIMUM |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 65.0 DC SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CQSM | Switch Location And Position Designation | INTERNAL AT POLE ONE |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC SINGLE LOCATION |
ADAT | Body Width | 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 SINGLE LOCATION |
CSSX | Switch Current Rating And Type In Amps | 10.0 AC AND 3.0 DC |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRX | Actuator Position Designation | AT POLE ONE |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
CPRW | Actuator Function | TRIP-RESET |
CSWP | Switch Voltage Rating And Type In Volts | 250.0 AC AND 50.0 DC |
AXHR | Mounting Facility Type And Quantity | 2 THREADED HOLE |
THSD | Thread Series Designator | UNC |
CQJX | Nominal Thread Size | 0.138 INCHES |
TTQY | Terminal Type And Quantity | 2 SCREW |
MRC | Decoded Requirement | Clear Text Reply |
AJWX | Mounting Surface To Terminal End Distance | 2.032 INCHES MAXIMUM |
ADTV | Case Material | PLASTIC |
AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
ADAQ | Body Length | 1.985 INCHES MINIMUM AND 2.015 INCHES MAXIMUM |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.515 INCHES MINIMUM AND 1.545 INCHES MAXIMUM |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
PKWT | Unpackaged Unit Weight | 2.200 OUNCES |
CMLP | Thread Quantity Per Inch | 32 |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 DC SINGLE LOCATION |
AFJN | Fragility Factor | MODERATELY RUGGED |
CRTK | Switch Terminal Type | SCREW |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 1.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 10.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CPRQ | Reset Method | MANUAL |
CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |
Guaranteed quotes back within
5 minutes, 24/7 x 365
All Orders are fulfilled in the USA.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
Don't Forget That We Can Give You a Quote for Parts Within 15 Minutes If You Fill Out The Instant RFQ Form On Our Page.