Are you in need of part numbers 3X1163SVMG4-60-416VAC400C13, 3X1163VMG4-60-416VAC400C13, 64-184-2-MG4 from Eaton Corporation manufacturers of NSN 5925008034539? ASAP Parts Online has the part number in stock and ready to be shipped. Along with NSN 5925008034539 corresponding part numbers, we have access to billions of premium parts such as Circuit Breaker for the aviation, defense, and military industries. We are here to help streamline the process.
Alternative NSN: 5925-00-803-4539 |
Item Name:Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 008034539 |
NCB Code: USA (00) |
Manufacturers: Eaton Corporation |
Part No Part No
|
Item Name Item Name
|
Manufacturer Manufacturer
|
QTY QTY
|
RFQ RFQ
|
---|---|---|---|---|
3X1163SVMG4-60-416VAC400C13 | circuit breaker | Eaton Corporation | Avl |
|
3X1163VMG4-60-416VAC400C13 | circuit breaker | Eaton Corporation | Avl |
|
64-184-2-MG4 | circuit breaker | Eaton Corporation | Avl |
|
MRC | Criteria | Characteristic |
---|---|---|
ADAQ | BODY LENGTH | 5 240 INCHES MINIMUM AND 5 260 INCHES MAXIMUM |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0 190 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 3 052 INCHES MINIMUM AND 3 072 INCHES MAXIMUM |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0 990 INCHES MINIMUM AND 1 010 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJEC | BOSS HEIGHT | 0 208 INCHES MINIMUM AND 0 228 INCHES MAXIMUM |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 12 THREADED HOLE AND 12 UNTHREADED HOLE |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 60 0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 416 0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000 0 AC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150 0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 3 TOGGLE |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE TWO AND THREE LINKED |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF AND FUNGUS PROOF |
CWJK | CASE MATERIAL | PLASTIC |
FREQ | FREQUENCY IN HERTZ | 400 0 ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 6 COMPRESSION |
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADAT | BODY WIDTH | 4 490 INCHES MINIMUM AND 4 510 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 2 677 INCHES MINIMUM AND 2 697 INCHES MAXIMUM |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 4 349 INCHES MINIMUM AND 4 369 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0 990 INCHES MINIMUM AND 1 010 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 3 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQJX | NOMINAL THREAD SIZE | 0 164 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0 320 MINIMUM AT 200 PCT AND 1 000 MAXIMUM AT 200 PCT ALL LOCATIONS |
THSD | THREAD SERIES DESIGNATOR | UNC |
Guaranteed quotes back within
5 minutes, 24/7 x 365
All Orders are fulfilled in the USA.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
Don't Forget That We Can Give You a Quote for Parts Within 15 Minutes If You Fill Out The Instant RFQ Form On Our Page.
Request for Quote