Are you in need of part numbers JC3-C3-15-2 from Eaton Corporation manufacturers of NSN 5925003361992? ASAP Parts Online has the part number in stock and ready to be shipped. Along with NSN 5925003361992 corresponding part numbers, we have access to billions of premium parts such as Circuit Breaker for the aviation, defense, and military industries. We are here to help streamline the process.
Alternative NSN: 5925-00-336-1992 |
Item Name:Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 003361992 |
NCB Code: USA (00) |
Manufacturers: Eaton Corporation |
Part No Part No
|
Item Name Item Name
|
Manufacturer Manufacturer
|
QTY QTY
|
RFQ RFQ
|
---|---|---|---|---|
JC3-C3-15-2 | circuit breaker | Eaton Corporation | Avl |
|
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | DUSTPROOF |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 15.0 AMPERES AC ALL LOCATIONS |
AKPX | Pole Quantity | 3 |
ABXD | Bushing Length | 0.098 INCHES MINIMUM AND 0.162 INCHES MAXIMUM |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.718 INCHES MINIMUM AND 0.782 INCHES MAXIMUM |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
TTQY | Terminal Type And Quantity | 6 QUICK DISCONNECT, MALE |
THSD | Thread Series Designator | UNC |
CPRX | Actuator Position Designation | AT EACH POLE |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
ADAT | Body Width | 2.218 INCHES MINIMUM AND 2.282 INCHES MAXIMUM |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRW | Actuator Function | TRIP-RESET |
ADTV | Case Material | PLASTIC |
CQJX | Nominal Thread Size | 0.138 INCHES |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
AJWX | Mounting Surface To Terminal End Distance | 1.898 INCHES MINIMUM AND 1.962 INCHES MAXIMUM |
ADAQ | Body Length | 1.968 INCHES MINIMUM AND 2.032 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.528 INCHES MINIMUM AND 1.592 INCHES MAXIMUM |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.718 INCHES MINIMUM AND 0.782 INCHES MAXIMUM |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CMLP | Thread Quantity Per Inch | 32 |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 22.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
CPRQ | Reset Method | MANUAL |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
MRC | Decoded Requirement | Clear Text Reply |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 1.628 INCHES MINIMUM AND 1.692 INCHES MAXIMUM |
Guaranteed quotes back within
5 minutes, 24/7 x 365
All Orders are fulfilled in the USA.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
Don't Forget That We Can Give You a Quote for Parts Within 15 Minutes If You Fill Out The Instant RFQ Form On Our Page.
Request for Quote