Are you in need of part numbers 1810-0398, 256CK223X2PD, 350-4044-010, 41561-279-00-5, 4310R-101-223 from Keysight Technologies Inc, Hewlett Packard Inc, Sprague Electric Co, Rockwell Collins Inc, British Aerospace Inc manufacturers of NSN 5905011037879? ASAP Parts Online has the part number in stock and ready to be shipped. Along with NSN 5905011037879 corresponding part numbers, we have access to billions of premium parts such as Resistor Network Fi for the aviation, defense, and military industries. We are here to help streamline the process.
Alternative NSN: 5905-01-103-7879 |
Item Name:Resistor Network Fi |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5905 Resistors |
NIIN: 011037879 |
NCB Code: USA (01) |
Manufacturers: Bae Systems Maritime Serviceslimited , Bourns Inc , Bourns Instruments Inc , Bourns Networks , British Aerospace Inc , Cts Co Inc , Harris Llc , Hewlett Packard Inc , Keysight Technologies Inc , Rockwell Collins Inc , Selex Es Limited , Sprague Electric Co , Woodward Hrt Inc |
Part No Part No
|
Item Name Item Name
|
Manufacturer Manufacturer
|
QTY QTY
|
RFQ RFQ
|
---|---|---|---|---|
1810-0398 | resistor network fi | Keysight Technologies Inc | Avl |
|
1810-0398 | resistor network fi | Hewlett Packard Inc | Avl |
|
256CK223X2PD | resistor network fi | Sprague Electric Co | Avl |
|
350-4044-010 | resistor network fi | Rockwell Collins Inc | Avl |
|
41561-279-00-5 | resistor network fi | British Aerospace Inc | Avl |
|
41561-279-00-5 | resistor network fi | Bae Systems Maritime Serviceslimited | Avl |
|
4310R-101-223 | resistor network fi | Bourns Inc | Avl |
|
4310R-101-223 | resistor network fi | Bourns Networks | Avl |
|
4310R101-223L | resistor network fi | Bourns Instruments Inc | Avl |
|
750-101-R22K | resistor network fi | Cts Co Inc | Avl |
|
84001092-002 | resistor network fi | Woodward Hrt Inc | Avl |
|
950-0010-223 | resistor network fi | Harris Llc | Avl |
|
VA-47-0491-009 | resistor network fi | Selex Es Limited | Avl |
|
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -250 0250 0 |
AAPP | ELECTRICAL RESISTANCE | 22 000 KILOHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -2 0002 000 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 25 0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 125 0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55 0125 0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARA | TERMINAL QUANTITY | 10 |
AARB | TERMINAL TYPE | PIN |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0 125 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0 995 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0 080 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0 190 INCHES MAXIMUM |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | LADDER NETWORK |
AEFB | POWER DISSIPATION RATING IN WATTS | 1 250 TOTAL NETWORK |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 9 EACH RESISTOR |
STYL | STYLE DESIGNATOR | SINGLE INLINE |
Guaranteed quotes back within
5 minutes, 24/7 x 365
All Orders are fulfilled in the USA.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
Don't Forget That We Can Give You a Quote for Parts Within 15 Minutes If You Fill Out The Instant RFQ Form On Our Page.