Are you in need of part numbers 108A223, 143240-011, 1810-0207, 208A223, 256CH223X2PD from Rockwell Automation Ltd, Harris Llc, Keysight Technologies Inc, Hewlett Packard Inc, Sprague Electric Co manufacturers of NSN 5905010332200? ASAP Parts Online has the part number in stock and ready to be shipped. Along with NSN 5905010332200 corresponding part numbers, we have access to billions of premium parts such as Resistor Network Fi for the aviation, defense, and military industries. We are here to help streamline the process.
Alternative NSN: 5905-01-033-2200 |
Item Name:Resistor Network Fi |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5905 Resistors |
NIIN: 010332200 |
NCB Code: USA (01) |
Manufacturers: Ametek Programmable Power Inc , California Instruments Corp , Cts Co Inc , Harris Llc , Hewlett Packard Inc , Howmet Corporation , Keysight Technologies Inc , Rockwell Automation Ltd , Sprague Electric Co , Vishay Dale Electronics Inc |
Part No Part No
|
Item Name Item Name
|
Manufacturer Manufacturer
|
QTY QTY
|
RFQ RFQ
|
---|---|---|---|---|
108A223 | resistor network fi | Rockwell Automation Ltd | Avl |
|
143240-011 | resistor network fi | Harris Llc | Avl |
|
1810-0207 | resistor network fi | Keysight Technologies Inc | Avl |
|
1810-0207 | resistor network fi | Hewlett Packard Inc | Avl |
|
208A223 | resistor network fi | Rockwell Automation Ltd | Avl |
|
256CH223X2PD | resistor network fi | Sprague Electric Co | Avl |
|
360154 | resistor network fi | California Instruments Corp | Avl |
|
360154 | resistor network fi | Ametek Programmable Power Inc | Avl |
|
750-81-R22K | resistor network fi | Howmet Corporation | Avl |
|
750-81-R22K | resistor network fi | Cts Co Inc | Avl |
|
CSC08A-01 223G | resistor network fi | Vishay Dale Electronics Inc | Avl |
|
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -100 0100 0 |
AAPP | ELECTRICAL RESISTANCE | 22 000 KILOHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -5 0005 000 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 70 0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 150 0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARA | TERMINAL QUANTITY | 8 |
AARB | TERMINAL TYPE | PIN |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0 110 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0 778 INCHES NOMINAL |
ADAT | BODY WIDTH | 0 080 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0 342 INCHES NOMINAL |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | LADDER NETWORK |
AEFB | POWER DISSIPATION RATING IN WATTS | 1 300 TOTAL NETWORK |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 7 EACH RESISTOR |
STYL | STYLE DESIGNATOR | SINGLE INLINE |
Guaranteed quotes back within
5 minutes, 24/7 x 365
All Orders are fulfilled in the USA.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
Don't Forget That We Can Give You a Quote for Parts Within 15 Minutes If You Fill Out The Instant RFQ Form On Our Page.
Request for Quote