Are you in need of part numbers NFJ434125-50 DEG C from Challenger Electrical Equipment Corp manufacturers of NSN 5925013126666? ASAP Parts Online has the part number in stock and ready to be shipped. Along with NSN 5925013126666 corresponding part numbers, we have access to billions of premium parts such as Circuit Breaker for the aviation, defense, and military industries. We are here to help streamline the process.
Alternative NSN: 5925-01-312-6666 |
Item Name:Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 013126666 |
NCB Code: USA (01) |
Manufacturers: Challenger Electrical Equipment Corp |
Part No Part No
|
Item Name Item Name
|
Manufacturer Manufacturer
|
QTY QTY
|
RFQ RFQ
|
---|---|---|---|---|
NFJ434125-50 DEG C | circuit breaker | Challenger Electrical Equipment Corp | Avl |
|
MRC | Criteria | Characteristic |
---|---|---|
ABMK | OVERALL WIDTH | 4 810 INCHES NOMINAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
CBBL | FEATURES PROVIDED | ADJUSTABLE TRIP RELEASE |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 600 0 AC AND 250 0 DC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000 0 AC AND 10000 0 DC ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | GENERAL PURPOSE |
FREQ | FREQUENCY IN HERTZ | 60 0 ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 6 COMPRESSION |
ABHP | OVERALL LENGTH | 9 560 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 4 130 INCHES NOMINAL |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 125 0 AMPERES AC AND 125 0 AMPERES DC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
CPSF | ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS | 700 0 TO 1250 0 AC AND 700 0 TO 1250 0 DC ALL LOCATIONS |
AAQL | BODY STYLE | RECTANGULAR DIMENSIONAL ENVELOPE |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0 196 INCHES NOMINAL |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKPX | POLE QUANTITY | 3 |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 50 0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CWJK | CASE MATERIAL | PLASTIC |
FEAT | SPECIAL FEATURES | AT 480 VACINTERRUPTING CURRENT CAPACITY IS 22000 AMPERES |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125 0 ALL LOCATIONS |
Guaranteed quotes back within
5 minutes, 24/7 x 365
All Orders are fulfilled in the USA.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
Don't Forget That We Can Give You a Quote for Parts Within 15 Minutes If You Fill Out The Instant RFQ Form On Our Page.
Request for Quote