Are you in need of part numbers 45-700-IG1-P10-2A, 2-5700-IG1-P10-2A, 088196-28, 00-088196-00028 from Oakland Industries Ltd, Hobart Corporation manufacturers of NSN 5925013107226? ASAP Parts Online has the part number in stock and ready to be shipped. Along with NSN 5925013107226 corresponding part numbers, we have access to billions of premium parts such as Circuit Breaker for the aviation, defense, and military industries. We are here to help streamline the process.
Alternative NSN: 5925-01-310-7226 |
Item Name:Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 013107226 |
NCB Code: USA (01) |
Manufacturers: Hobart Corporation , Oakland Industries Ltd |
Part No Part No
|
Item Name Item Name
|
Manufacturer Manufacturer
|
QTY QTY
|
RFQ RFQ
|
---|---|---|---|---|
45-700-IG1-P10-2A | circuit breaker | Oakland Industries Ltd | Avl |
|
2-5700-IG1-P10-2A | circuit breaker | Oakland Industries Ltd | Avl |
|
088196-28 | circuit breaker | Hobart Corporation | Avl |
|
00-088196-00028 | circuit breaker | Hobart Corporation | Avl |
|
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ADAQ | BODY LENGTH | 1 140 INCHES NOMINAL |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 2 0 AMPERES AC AND 2 0 AMPERES DC SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CWJK | CASE MATERIAL | PLASTIC |
ABXD | BUSHING LENGTH | 0 400 INCHES NOMINAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0 780 INCHES NOMINAL |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2 220 INCHES NOMINAL |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250 0 AC AND 28 0 DC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2000 0 AC AND 2000 0 DC SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 10 000 MINIMUM AT 200 PCT AND 40 000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF |
ADAT | BODY WIDTH | 0 570 INCHES NOMINAL |
AKPX | POLE QUANTITY | 1 |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125 0 SINGLE LOCATION |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
FREQ | FREQUENCY IN HERTZ | 60 0 SINGLE LOCATION |
TTQY | TERMINAL TYPE AND QUANTITY | 2 QUICK DISCONNECT MALE |
Guaranteed quotes back within
5 minutes, 24/7 x 365
All Orders are fulfilled in the USA.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
Don't Forget That We Can Give You a Quote for Parts Within 15 Minutes If You Fill Out The Instant RFQ Form On Our Page.
Request for Quote